A fire alarm system has a number of devices working together to detect and warn people through visual and audio appliances when smoke, fire, carbon monoxide or other emergencies are present. These alarms may be activated automatically from smoke detectors, and heat detectors or may also be activated via manual fire alarm activation devices such as manual call points or pull stations. Alarms can be either motorized bells or wall mountable sounders or horns. They can also be speaker strobes which sound an alarm, followed by a voice evacuation message which warns people inside the building not to use the elevators. Fire alarm sounders can be set to certain frequencies and different tones including low, medium and high, depending on the country and manufacturer of the device.
Our Testing Standards
BS 5446-1 Fire detection and fire alarm devices for dwellings Part 1 Specification for smoke alarms
BS 5446-2 Fire detection and fire alarm devices for dwellings Part 2 Specification for heat alarms
BS 5446-3 Specification for smoke alarm kits for deaf and hard of hearing people
CEA 4021 Requirements and test methods for multisensor detectors, which respond to smoke and heat, and smoke detectors with more than one smoke sensor
EN 54-2 Fire detection and fire alarm systems - Control and indicating equipment
EN 54-3 Sounders
EN 54-4 Fire detection and fire alarm systems - Power supply equipment
EN 54-5 Heat detectors - point detectors
EN 54-7 Smoke detectors - point detectors using scattered light, transmitted light or ionisation
EN 54-10 Flame detectors - point detectors
EN 54-11 Manual call points
EN 54-12 Smoke detectors - line detectors using an optical light beam
EN 54-13 Compatibility assessment for system components
EN 54-16 Voice Alarm Control and Indicating Equipment.
EN 54-17 Short-circuit isolators
EN 54-18 Input/output devices
EN 54-21 Fire detection and fire alarm systems - Alarm transmission and fault warning routing equipment
EN 54-24 Loudspeakers
EN 54-25 Components using radio links
EN 14604 Smoke alarm devices
EN 50291 Electrical apparatus for the detection of Carbon monoxide in domestic premises - Test method and performance requirements
EN 50291-1 Electrical apparatus for the detection of Carbon monoxide in domestic premises - Test method and performance requirements
EN 50291-2 Electrical apparatus for the detection of Carbon monoxide in domestic premises - Part 2: Electrical apparatus for continuous operation in a fixed installation in recreational vehicles and similar premises including recreational craft-Additional test method and performance requirements.
ISO 7240-2 Control and Indicating Equipment;
ISO 7240-4 Power supply equipment
ISO7240-5 Point -type heat detectors
ISO7240-6 Carbon monoxide fire detectors using electro-chemical cells
ISO7240-7 Point-type smoke detectors using scattered light, transmitted light or ionization
ISO 7240-11 Manual call points
ISO7240-12 Line type smoke detectors using transmitting light beam
NFPA72 - National Fire Alarm and Signaling Code, 2019 Edition
UL268 - Smoke Detectors for Fire Alarm Systems
UL864 - Standard for Control Units and Accessories for Fire Alarm Systems
FM3260 - Radiant Energy-Sensing Fire Detectors for Automatic Fire Alarm Signaling
FM3265 -Spark Detection and Extinguishing Systems